Add to Cart
PDrop Pressure Calculation
Software
The Fastest and Easiest Way to
Calculate Pressure Drops in HVAC Systems!
Most HVAC
ductwork and piping systems are sized using duct-u-lators and pipe
sizing tables respectively. Its done this way by thousands
of engineers and contractors for one simple reason - its the fastest
method. However, after sizing the systems, an accurate pressure drop must be
calculated to size the fan or pump. A mistake can cause
costly change orders.
P-DROP
quickly and easily calculates air pressure drop in duct systems
that have been sized using a duct-u-lator. The software also calculates
water pressure drop for systems sized by charts.
These
pressure drops can be used to select fans and pumps more accurately.
P-DROP
was developed by Design and Consulting Engineers for use by Engineers,
Contractors, and Architects. The program has been used daily
by engineers on thousands of actual projects all over the United
States, the Middle East, Australia, and other countries.
FEATURES
-
Calculates
Air Pressure Drop in Supply, Return, and Exhaust Ductwork
systems.
-
Calculates
allowable duct clearances and prints detail
-
Calculates
Pump Head Pressure for Open or Closed Systems.
-
Reduce
Design Errors.
-
Reduces
design time.
-
Easy
to Learn Spreadsheet Type Interface.
-
Saves
calculations in project friendly format.
-
Prints
out all calculations for great-looking documentation
Quality
control will be improved in the design of all projects since the
program helps users not to "forget" important pressure losses
in duct and piping systems.
Ductwork
Pressure Drop
Fan Demo
P-DROP
allows you to quickly calculate air pressure drops for any fan,
AHU, DX, FCU and other HVAC or fan system. Simply size the
ductwork using your duct-u-lator as you always have. Then
select the most critical leg of the system. It only takes 2 minutes to enter the information into the
P-Drop program for each fan system.
You may
customize the calculations based upon average friction drop and
average velocity used to size the system. Standard loss
coefficients for each type of device is included, but you may
customize as you wish.
Piping
System Pressure Drop
Pump Demo
P-DROP
also uses a simplified approach to calculate the head pressure
drop in the most critical leg of a piping system that has been
sized using a pipe sizing chart or tool.
But P-DROP
takes 1/10 the time to estimate pressure drop when compared
to other computer programs. The input
only takes a couple of minutes instead of hours required by the
Trane, ELITE, and Carrier programs.
Never
underestimate pump head again! P-DROP's simplified method has
been used by Consulting Engineers for years to quickly and accurately
calculate head loss without entering a lot of data.
Using
the P-DROP method will reduce design time and make sure fans and
pumps are sized correctly.
PROJECT
FRIENDLY. The program
helps document design calculations and allows you to save design
data for multiple projects. This helps organize all fans
and pump calculation for a job in one file so changes can be made
in seconds.
Bonus
Feature - Ceiling Clearance Calculator
Do you
know how Architects never want to give you enough ceiling
clearance? One of
the most critical calculations needed at the beginning of every
job is to calculate how much space is needed for ducts and piping.
P-Drop not only calculates the maximum duct depth with existing
structures, but the printout can be faxed to an architect so they
understand ceiling space requirements graphically for new
buildings. This lets even junior engineers get it right
without forgetting things like structure, lights, fire protection, and duct
insulation.
Minimum System Requirements:
-
Windows 2000, Xp
-
15 MB HD
-
256k Memory
|